Description
Benefits
- Ideal for measuring tasks that require maximum precision
- Clamp-on flow system for the measurement of liquids, oil, or gas
- Suitable for new installations as well as retrofitting
- Designed for use with up to 4 paths
- Designed for use in Ex areas, a safe distance to the transmitter of up to 150 m
- Fast signal processing with a 100 Hz update rate
- High accuracy, repeatability, and zero flow detection
- Downward compatible with all sensors of the SITRANS FUS1011 family
- Replacement device for SITRANS FUS1010, FUH1010 or FUG1010
- Designed according to NAMUR requirements and Industry 4.0 with various diagnostic functions
Applications:
Drinking water supply, water networks, cooling water in power plants, chemical liquids (Ex areas possible), crude oil providers and pipeline operators (product and margin detection, leakage detection, pig runs), gas transport, and gas providers in high-pressure grids.
Technical Specifications
Enclosure | Wallmount enclosure: die-cast aluminum, painted, wall or standpipe mounting options, IP65/NEMA 4X for Ex zone 2 or Class 1 Div 2
Industrial enclosure: die-cast aluminum, painted, wall or standpipe mounting options, IP65/NEMA 4X for Ex zone 1/2 or Class 1 Div 1/2 Digital Sensor Link (DSL) – external variant up to 4-path: die-cast aluminum, painted, IP68, for use in Zone 0/1 or Class 1 Div 1/2 |
---|---|
Sensors | FSS200 Sensors (Clamp-On) In the universal or high precision version (up to max. 120 ° C / 250 ° F) or high temperature (up to 230°C/446°F), for use in Zone 0/1 or Class 1 Div 1/2 |
Process values (primary) | Volume flow
Mass flow Standard volume flow Flow velocity Speed of sound Liquident detection Totalizer 1, 2 and 3 |
Communication | HART or Modbus RTU; compatible with SIMATIC PDM; USB service port |
Data logger | 4GB SD card, expandable to 32 GB
Data logging in table format (.csv) for: measurement data, alarms, incidents, firmware updates Logging interval programmable from 1s – 24 hours |
I/O options | 3 in/outputs: channel 2, 3 and 4: 4-20 mA active/passive, status output, relay
Inputs channel 5 and 6 on external SITRANS FS DSL: 2 x temperature PT100/500/1000 or 2 x analogue (temperature and pressure) |
Display | Full-graphic display, 240 x 160 pixel, backlit |
Power supply | 24 V DC / 90 – 240 VAC |
Approvals | UL, cUL, CE, ATEX, FM, and more |
Measuring accuracy | ≥ 0,3% |
Flow range | Liquids ±12 m/s (±40 ft/s), gas, ±40 m/s and more; bidirectional |
Pipe diameters | 12,7 mm to 10 m (0.5″ to 394″) |